No Shedding DC UPS

No Shedding DC UPS

R 1,099.00
SKU:
NS-UPS100-95
ALL PRICES DISPLAYED ARE EXCLUSIVE OF VAT.

ACCESSORIES ARE SOLD SEPARATELY.
NOT SURE WHAT TO ORDER? CONTACT US TODAY!

Vendor:

NviroSense's NS-UPS-100 or the NO Shedding DC UPS is an efficient, compact, and reliable uninterruptible power supply, available with a VRLA GEL technology battery with its proprietary grid alloy and paste formulation, provides superior performance in both high cycling and floating applications.

Designed specifically to keep your gateway connected at all times. A small but rugged form factor contains superior performance and flexibility.

Available in the following options:

  1. 5v-9v (Battery Included) - South Africa Only (Part No. NS-UPS100-95)
  2. 5v-12v (Battery Included) - South Africa Only (Part No. NS-UPS100-125)
  3. 9v - 12v (Battery Included) - South Africa Only (Part No. NS-UPS100-129)
  4. 5v-9v - 12v (Battery not included) - Europe, UAE (Part No. NS-UPS100-95-INT)
  5. 5v-12v (Battery not included) - Europe, UAE (Part No. NS-UPS100-125-INT)
  6. 9v - 12v (Battery not included) - Europe, UAE (Part No. NS-UPS100-129-INT)

Highlighted Features

  • Low power consumption, high reliability.

  • 100% full load burn-in test.

  • An audible tone for mains fails that can be enabled or disabled through a link.

  • AC Failure.

  • Battery protection circuit built-in.

  • Battery charger with intelligent switch-mode charging processed by a processor

Maintenance & Caution

  • Ensure all batteries operating in a series-based connection are not discharged excessively.;
  • Batteries must be charged with the correct voltage;
  • Recharge capacity will be 1.1 - 1.15 times the discharge capacity;
  • Effect of temperature on cycle charge voltage: -5mV/degrees per cell;
  • It is imperative the battery is always in an upright position and never on its side.

Factors Affecting Battery Life

  • Depth of discharge
  • Temperature
  • Recharge rate
  • Refer to Technical Specifications*

SPECIFICATIONS

PHYSICAL ATTRIBUTES

Enclosure

High-grade industrial plastic

Cold Start

lSA/llSVac, 30A/230Vac

Protection

Overload Protection:
115% - 135% of the rated power; pulsing hiccup shut down; and auto-recovery.

Over Voltage Protection:
Short Circuit Protection & Recovery; AC failure; battery protection.

    Power Consumption

    Low

    Battery

    5V, 12V, with 9V on request

    Voltage

    Output: 5V (available), 9V (on request), 12V

    Input: 220v

    Charger

    Intelligent switch-mode charging processed by the processor

    Run Time Without Electricity

    4+ hours *dependent on load

    Max Load

    4 Amp

    Charging Current

    1 Amp

    LED

    Red/Green

    Audible Tones

    Power Up: Continuous beep for 3 seconds

    Power Failure: Beeps every 30 seconds

    Battery Cut-off: 30 seconds WARNING beep before the unit cuts off the battery voltage

    Environmental

    Discharge: -15-50°C

    Charge: -15-40°C

    Storage: -15-40°C

    Regulatory

    Complies with EN55022, EN61000-3-2, 3, EN55024, SANS IEC60950

    Warranty

    One-year

    BATTERY ATTRIBUTES

    Battery Dimensions

    L 151mm x W 65mm x H 99mm

    Approximate Weight

    2.4 kg (5.29 lbs)

    Nominal Voltage

    12 (6 Cells per unit)

    Designed Floating Life (20°C)

    10 Years

    Nominal Capacity (20°C)

    8 Ah @ 20HR-rate (to 1.75Vpc)

    Terminal Type

    Fasten Tab F1

    Internal Resistance

    Approximately 0.02mΩ (fully charged @ 20°C)

    Max. Charge Current

    2.4A

    Max. Discharge Current (5S)

    105A

    Short Circuit Current

    600A

    Self Discharge

    Approximately 3% per month @ 20°C

    Ambient Temperature

    Discharge: -15-50°C

    Charge: -15-40°C

    Storage: -15-40°C

    Float Charge Voltage (20 - 25°C)

    13.6-13.8V (-3mV/ cell/ °C)

    Equalize & Cycle Use Charge Voltage (20 -25°C)

    14.4-14.8V (-5mV/ cell/ °C)

    Container Material

    ABS (UL94-V0 optional)

    UPS OPERATION

    Caution

    Read the instructions carefully before installing the UPS.

    Use this equipment only in an indoor application. Mounting, Maintenance, and repair must be carried out by a skilled and authorized person, and always ensure the mains are off when wiring this unit.


      Connecting

      Disconnect the mains before wiring up the equipment to the unit. Before connecting the battery, plug the unit into the mains, the unit will generate a small amount of heat so ensure the unit is installed in an area with sufficient ventilation. This unit should not be installed outdoors as it is not weather-resistant.

        Audible Tone

        Power Up: Continuous beep for 3 seconds

        Power Failure: Beeps every 30 seconds

        Battery Cut Off: 30 seconds WARNING beep before the unit cuts off the battery voltage.

        LED Indication

        Red, Green, Buzzer, No Buzzer

        Battery Charging

        GREEN LED FLASH

        Battery Fully Charged

        GREEN LED

        No Mains - Battery Voltage OK

        RED LED FLASHING - BUZZER ON

        No Mains - Battery Voltage Below 10.5V

        RED LED FLASHING - BUZZER ON